NFEEDER β PRECISION INSECT FEEDING SYSTEM
Version 3.0 | Intelligent Feeding Technology
β οΈ SAFETY & MAINTENANCE
FEED TYPE
Only use live insects or dry feed. Never use liquids or wet materials.
MAINTENANCE
Always disconnect the power supply before cleaning or servicing the feeder.
ANIMAL WELFARE
Overfilling may cause clogging and increased insect mortality.
πΉοΈ CONTROL PANEL
Use the buttons around the display:
- ENTER β Select / Confirm
- UP / DOWN β Adjust values
- PREV / NEXT β Navigate between settings
βοΈ STANDARD SETTINGS
Drive & Core Behavior
| Function | Default | Description |
|---|---|---|
| Batch Amount | 1 | Number of insects per release |
| Speed | 20% | Pusher speed |
| Friendly Mode | OFF | Closing behavior |
| Closer Speed | FAST | Closing speed (No Mercy mode) |
Batch Amount
Quick Guide
Sets how many insects are released per cycle (1β5).
Technical Insight
Defines the batch size per dump cycle. Higher values increase output but raise the risk of clogging.
β οΈ Warning: Excessive values may block the fall tunnel.
Wait at Rest Position
Quick Guide
The feeder remains in dump position after feeding.
Technical Insight
Keeps the pusher in place to ensure all insects fully drop before retracting.
AutoMode
Quick Guide
Active = automatic feeding, Stand-by = off.
Technical Insight
Controls the full automatic cycle: detection, capture, and dispensing.
Rehome
Quick Guide
Resets the feeder to its starting position.
Technical Insight
Reinitializes the system and clears error states.
Feeding Schedule
| Function | Description |
|---|---|
| Schedule | Configure weekly feeding |
| Start Schedule | Set daily start time |
Schedule
Quick Guide
Select day, amount, and time.
Technical Insight
Programs up to 7 daily feeding cycles using the internal clock.
Start Schedule
Quick Guide
Defines when the feeding cycle starts.
Technical Insight
Triggers the first cycle of the day.
Setup Time
Quick Guide
Set date and time.
Technical Insight
Essential for accurate scheduling.
Behavior & Optimization
| Function | Default | Description |
|---|---|---|
| Shake Intensity | 1 | Lower = stronger |
| Shake Duration | 2s | Shake duration |
| Shake Interval | 30 | Time between shakes |
| Hunters Eyeβs | ON | LED attraction |
Shake Intensity & Duration
Quick Guide
Adjust shaking strength and duration.
Technical Insight
Prevents insect clustering and ensures consistent feeding flow.
Shake Interval
Quick Guide
Time between shake cycles.
Technical Insight
Reduces energy use and prevents constant vibration.
Hunters Eyeβs
Quick Guide
Activates LEDs to attract insects.
Technical Insight
Uses light to influence insect behavior and improve detection rate.
Friendly Mode
Quick Guide
Soft Close = gentle
No Mercy = fast and efficient
Technical Insight
Trade-off between animal-friendly behavior and accuracy.
Closer Speed
Quick Guide
Controls closing speed.
Technical Insight
Affects capture efficiency and mechanical stress.
π SUPER USER SETTINGS
Detection & Sensors
| Function | Default | Description |
|---|---|---|
| Insect Fingerprint | 24 | Reference value per insect |
| Flash Strength | 100 | Light intensity |
| Flash Sample | 0 | Number of readings |
| Flash Threshold | 0 | Minimum valid readings |
| Flash Duration | 50ms | Flash time |
Insect Fingerprint
Quick Guide
Calibrate what β1 insectβ looks like.
Technical Insight
Defines the reference detection value (pt) per insect.
Flash Strength
Quick Guide
Adjust detection light power.
Technical Insight
Balances precision versus stability.
Flash Sample
Quick Guide
Number of readings per detection.
Technical Insight
More samples reduce noise but slow down detection.
Flash Threshold
Quick Guide
Minimum required valid readings.
Technical Insight
Filters out false detections.
Flash Duration
Quick Guide
Duration of each flash.
Technical Insight
Impacts sensor exposure and accuracy.
Mechanical Fine-Tuning
| Function | Default | Description |
|---|---|---|
| Offset Detection Position | 1850 | Sensor alignment |
| Read LDR DTC | OFF | Sensor readout |
| Reset Daily Counter | OFF | Reset daily count |
Offset Detection Position
Quick Guide
Adjust alignment.
Technical Insight
Ensures insects pass through the optimal detection point.
Read LDR DTC
Quick Guide
View sensor value.
Technical Insight
Used for diagnostics only.
Reset Daily Counter
Quick Guide
Reset daily insect count.
Technical Insight
Clears stored daily data.
β οΈ SUPER SETTINGS (ADVANCED)
For experienced users only. Incorrect values may cause instability or damage.
Core Parameters
| Function | Default | Description |
|---|---|---|
| Feedback | 1000 | Jam detection |
| Fall Position | 11000 | Drop position |
| Fast Close Offset | 1000 | Closing offset |
Feedback
Quick Guide
Protects against jamming.
Technical Insight
Compares encoder movement with expected motion.
Fall Position
Quick Guide
Defines where insects are released.
Technical Insight
Precise mechanical reference point.
Fast Close Offset
Quick Guide
Controls how far the door closes.
Technical Insight
Balances escape prevention vs mechanical safety.
Calibration
| Function | Default | Description |
|---|---|---|
| DTC N-Kal Offset | 10 | Sensor offset |
| K-Cal Position | 2590 | Calibration position |
DTC N-Kal Offset
Quick Guide
Prevents negative readings.
Technical Insight
Shifts the sensor baseline after calibration.
K-Cal Position
Quick Guide
Calibration position.
Technical Insight
Defines where calibration occurs in the system.
πΎ SYSTEM
| Function | Description |
|---|---|
| Reset to Factory Default | Restore factory settings |
| Save | Save all changes |
| Information | System info |
| Exit | Exit menu |
Reset to Factory Default
Restores all parameters. Save to make permanent.
Save
Stores all settings in memory.
Information
Displays firmware and system details.
Exit
Leaves the menu without saving changes.
β οΈ CRUCIAL
Proper configuration is essential for reliable operation.
β Use standard settings as baseline
β Adjust advanced settings only when needed
β Test changes step-by-step
π When properly configured, the NFeeder ensures:
- Consistent feeding
- Minimal errors
- Maximum reliability